Loading...
Thumbnail Image
Item

Criterion validity, and interunit and between-day reliability of the FLEX for measuring barbell velocity during commonly used resistance training exercises

Weakley, Jonathon
; 
Chalkley, Daniel
; 
Johnston, Rich
; 
García-Ramos, Amador
; 
Townshend, Andrew
; 
Dorrell, Harry
; 
Pearson, Madison
; 
Morrison, Matthew
; 
Cole, Michael
Citations
Google Scholar:
Altmetric:
Abstract
The aim of this study was to assess the criterion validity, interunit reliability (accounting for technological and biological variance), and between-day reliability of a novel optic laser device (FLEX) for quantifying mean concentric velocity. To assess the validity against a three-dimensional motion capture system and interunit reliability with both technological and biological variation, 18 men and women completed repetitions at 20, 40, 60, 80, 90, and 100% of one repetition maximum in the free-weight barbell back squat and bench press. To assess interunit (technological only) reliability, a purpose-built, calibrated rig completed a set protocol with 2 devices. To assess between-day reliability of the technology, the same protocol was repeated 21 days later. Standardized bias, typical error of the estimate (TEE; %), and Pearson's correlation coefficient (r) were used to assess validity, whereas typical error and coefficient of variation (CV%) were calculated for reliability. Overall, TEE (±90 CL) between the FLEX and criterion measure was 0.03 (±0.004) and 0.04 (±0.005) m·s−1 in the back squat and bench press, respectively. For measures of reliability, overall interunit technological variance (CV% [± 90% confidence interval]) was 3.96% (3.83–4.12) but increased to 9.82% (9.31–10.41) and 9.83% (9.17–10.61) in the back squat and bench press, respectively, when biological variance was introduced. Finally, the overall between-day reliability was 3.77% (3.63–3.91). These findings demonstrate that the FLEX provides valid and reliable mean concentric velocity outputs across a range of velocities. Thus, practitioners can confidently implement this device for the monitoring and prescription of resistance training loads.
Keywords
back squat, bench press, mean concentric velocity, velocity-based training, measurement
Date
2020
Type
Journal article
Journal
Journal of Strength and Conditioning Research
Book
Volume
34
Issue
6
Page Range
1519-1524
Article Number
ACU Department
School of Behavioural and Health Sciences
Faculty of Health Sciences
Relation URI
Source URL
Event URL
Open Access Status
License
File Access
Controlled
Notes